Publication type: Conference other
Type of review: Peer review (abstract)
Title: Use of an industrial robot to record human knee kinematics in vitro - evaluation of the test method
Authors: Nusser, Michaela
Kiener, Luca
Tschupp, Gabriel
et. al: No
Conference details: 28th Congress of the European Society of Biomechanics (ESB), Maastricht, The Netherlands, 9 -12 July 2023
Issue Date: Jul-2023
Language: English
Subjects: Test method; Industrial robot; In vitro knee kinematics
Subject (DDC): 571: Physiology and related subjects
610.28: Biomedicine, biomedical engineering
Abstract: Introduction: In vitro experiments using 6-axis industrial robots are a common method for studying human knee kinematics, recording passive path (PP) during flexion, and measuring knee laxity at various angles. There is only limited research on the reliability of this test setup even if it has been used countless times for in vitro experiments. To ensure reliability, the robot should have an automated determination of the forceand torque-free point at 0° flexion, high reproducibility, and sensitivity Method: Test specimens: An anonymized fresh-frozen human cadaveric right knee specimen with medial and lateral unicondylar knee prothesis was tested. Robot set up: All tests were carried out with a 6-df robotic system (KUKA KR 150; KUKA Robotics) equipped with a 6-component force-torque sensor (Omega 160 IP60; ATI Industrial Automation, tolerances: force 2.5N, moment: 0.5Nm). Finding the force and moment free state at 0° flexion: The goal was to develop a Matlab routine that automatically calculates the starting position, where no forces or torques are acting on the knee except for its own weight. The script determines the load on the robot arm and calculates the position where the knee is in a force-free and torque-free state, which will be used as the starting point of PP and the forces and moments will be set to zero. To test the accuracy of the tare program (TP), the tare point was determined 20 times. After each attempt, a manipulation was performed (e.g., internal rotation), and it was checked if the target values for forces and moments were within the measurement tolerances of the robot sensor. Reproducibility of the passive path (PP): The PP from 0° to 60° was repeated 21 times using the same starting point. The leg was unclamped and clamped again after each trial. Mean and standard deviation were determined for anterior-posterior displacement, internal and external rotation as well as varus and valgus moments. Results: Validation of tare program: The TP works well and has a hit rate of 90% across all force and moment directions. The most inaccurate is the regulation of the varus and valgus moments where five measurements were outside the tolerance. Reproducibility of passive path: Even with the same starting point 21 repetitions of PP cannot hit the same path twice. The largest range of correct solutions is observed for internal and external rotation. Discussion: TP can determine knee force- and moment-free state at desired knee angle reliably and is more accurate than a manual search. The reproducibility study of PP showed that many solutions exist for finding force and moment-free state for a knee flexion. This finding is particularly important for studies comparing cadaver knee prosthesis kinematics to the native state. Therefore, analyse absolute, not relative values when measuring laxity. Further, ligament tension and thus the knee stiffness decreases with each pass of passive pathway due to both increased ligament stretching and temperature changes in the specimen and room. Conditioning of the leg according to the same protocol before the test is therefore recommended.
URI: https://digitalcollection.zhaw.ch/handle/11475/28441
Fulltext version: Published version
License (according to publishing contract): Licence according to publishing contract
Departement: School of Engineering
Organisational Unit: Institute of Mechanical Systems (IMES)
Published as part of the ZHAW project: Entwicklung einer unikondylären Kniegelenksprothese mit physiologischer Kinematik
Appears in collections:Publikationen School of Engineering

Files in This Item:
There are no files associated with this item.
Show full item record
Nusser, M., Kiener, L., & Tschupp, G. (2023, July). Use of an industrial robot to record human knee kinematics in vitro - evaluation of the test method. 28th Congress of the European Society of Biomechanics (ESB), Maastricht, the Netherlands, 9 -12 July 2023.
Nusser, M., Kiener, L. and Tschupp, G. (2023) ‘Use of an industrial robot to record human knee kinematics in vitro - evaluation of the test method’, in 28th Congress of the European Society of Biomechanics (ESB), Maastricht, The Netherlands, 9 -12 July 2023.
M. Nusser, L. Kiener, and G. Tschupp, “Use of an industrial robot to record human knee kinematics in vitro - evaluation of the test method,” in 28th Congress of the European Society of Biomechanics (ESB), Maastricht, The Netherlands, 9 -12 July 2023, Jul. 2023.
NUSSER, Michaela, Luca KIENER und Gabriel TSCHUPP, 2023. Use of an industrial robot to record human knee kinematics in vitro - evaluation of the test method. In: 28th Congress of the European Society of Biomechanics (ESB), Maastricht, The Netherlands, 9 -12 July 2023. Conference presentation. Juli 2023
Nusser, Michaela, Luca Kiener, and Gabriel Tschupp. 2023. “Use of an Industrial Robot to Record Human Knee Kinematics in Vitro - Evaluation of the Test Method.” Conference presentation. In 28th Congress of the European Society of Biomechanics (ESB), Maastricht, the Netherlands, 9 -12 July 2023.
Nusser, Michaela, et al. “Use of an Industrial Robot to Record Human Knee Kinematics in Vitro - Evaluation of the Test Method.” 28th Congress of the European Society of Biomechanics (ESB), Maastricht, the Netherlands, 9 -12 July 2023, 2023.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.