Please use this identifier to cite or link to this item:
https://doi.org/10.21256/zhaw-23424
Publication type: | Article in scientific journal |
Type of review: | Peer review (publication) |
Title: | Development and clinical validation of the LymphMonitor technology to quantitatively assess lymphatic function |
Authors: | Polomska, Anna Gousopoulos, Epameinondas Fehr, Daniel Bachmann, Andreas Bonmarin, Mathias Detmar, Michael Lindenblatt, Nicole |
et. al: | No |
DOI: | 10.3390/diagnostics11101873 10.21256/zhaw-23424 |
Published in: | Diagnostics |
Volume(Issue): | 11 |
Issue: | 10 |
Page(s): | 1873 |
Issue Date: | 12-Oct-2021 |
Publisher / Ed. Institution: | MDPI |
ISSN: | 2075-4418 |
Language: | English |
Subjects: | Indocyanine green; Lymphatic function monitoring; Lymphatic system; Lymphedema; Lymphography; Mobile health |
Subject (DDC): | 610: Medicine and health |
Abstract: | Current diagnostic methods for evaluating the functionality of the lymphatic vascular system usually do not provide quantitative data and suffer from many limitations including high costs, complexity, and the need to perform them in hospital settings. In this work, we present a quantitative, simple outpatient technology named LymphMonitor to quantitatively assess lymphatic function. This method is based on the painless injection of the lymphatic-specific near-infrared fluorescent tracer indocyanine green complexed with human serum albumin, using MicronJet600TM microneedles, and monitoring the disappearance of the fluorescence signal at the injection site over time using a portable detection device named LymphMeter. This technology was investigated in 10 patients with unilateral leg or arm lymphedema. After injection of a tracer solution into each limb, the signal was measured over 3 h and the area under the normalized clearance curve was calculated to quantify the lymphatic function. A statistically significant difference in lymphatic clearance in the healthy versus the lymphedema extremities was found, based on the obtained area under curves of the normalized clearance curves. This study provides the first evidence that the LymphMonitor technology has the potential to diagnose and monitor the lymphatic function in patients. |
URI: | https://digitalcollection.zhaw.ch/handle/11475/23424 |
Fulltext version: | Published version |
License (according to publishing contract): | CC BY 4.0: Attribution 4.0 International |
Departement: | School of Engineering |
Organisational Unit: | Institute of Computational Physics (ICP) |
Appears in collections: | Publikationen School of Engineering |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
2021_Polomska_Development_and_clinical_validation_of_the_LymphMonitor_Technology_MDPI.pdf | 1.76 MB | Adobe PDF | ![]() View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.