Please use this identifier to cite or link to this item: https://doi.org/10.21256/zhaw-3348
Full metadata record
DC FieldValueLanguage
dc.contributor.authorMüller, Dominic-
dc.contributor.authorHeinlein, Bernd-
dc.contributor.authorDenzler, Dario-
dc.date.accessioned2019-03-29T09:39:42Z-
dc.date.available2019-03-29T09:39:42Z-
dc.date.issued2017-
dc.identifier.issn2398-5305de_CH
dc.identifier.urihttps://digitalcollection.zhaw.ch/handle/11475/16446-
dc.description.abstractPostoperative pain and functional limitations after an Anterior Cruciate Ligament reconstruction is usually inaccurate placement of the femoral and tibial tunnel. This paper presents a technology workflow including a software pipeline for patient-specific preoperative planning and analysis of the knee joint including functional-mechanical properties.de_CH
dc.language.isoende_CH
dc.publisherEasyChairde_CH
dc.relation.ispartofseriesEPiC series in health sciencesde_CH
dc.rightsLicence according to publishing contractde_CH
dc.subjectPatient-specific planningde_CH
dc.subjectPreoperative planning of ACL reconstructionde_CH
dc.subjectVirtual second opinionde_CH
dc.subject.ddc617: Chirurgiede_CH
dc.titleApplication specific adaption of a numerical based surgical processde_CH
dc.typeKonferenz: Paperde_CH
dcterms.typeTextde_CH
zhaw.departementSchool of Engineeringde_CH
zhaw.organisationalunitInstitut für Mechanische Systeme (IMES)de_CH
dc.identifier.doi10.21256/zhaw-3348-
dc.identifier.doi10.29007/44wqde_CH
zhaw.conference.detailsCAOS International 2017, Aachen, Germany, 14-17 June 2017de_CH
zhaw.funding.euNode_CH
zhaw.originated.zhawYesde_CH
zhaw.pages.end53de_CH
zhaw.pages.start51de_CH
zhaw.publication.statuspublishedVersionde_CH
zhaw.series.number1de_CH
zhaw.publication.reviewPeer review (Abstract)de_CH
zhaw.title.proceedingsCAOS International 2017, 17th Annual Meeting of the International Society for Computer Assisted Orthopaedic Surgeryde_CH
Appears in collections:Publikationen School of Engineering

Files in This Item:
File Description SizeFormat 
2017_Mülller_Application_specific_adaption_of_a_numerical_based_surgical_process.pdf273.27 kBAdobe PDFThumbnail
View/Open
Show simple item record
Müller, D., Heinlein, B., & Denzler, D. (2017). Application specific adaption of a numerical based surgical process [Conference paper]. CAOS International 2017, 17th Annual Meeting of the International Society for Computer Assisted Orthopaedic Surgery, 51–53. https://doi.org/10.21256/zhaw-3348
Müller, D., Heinlein, B. and Denzler, D. (2017) ‘Application specific adaption of a numerical based surgical process’, in CAOS International 2017, 17th Annual Meeting of the International Society for Computer Assisted Orthopaedic Surgery. EasyChair, pp. 51–53. Available at: https://doi.org/10.21256/zhaw-3348.
D. Müller, B. Heinlein, and D. Denzler, “Application specific adaption of a numerical based surgical process,” in CAOS International 2017, 17th Annual Meeting of the International Society for Computer Assisted Orthopaedic Surgery, 2017, pp. 51–53. doi: 10.21256/zhaw-3348.
MÜLLER, Dominic, Bernd HEINLEIN und Dario DENZLER, 2017. Application specific adaption of a numerical based surgical process. In: CAOS International 2017, 17th Annual Meeting of the International Society for Computer Assisted Orthopaedic Surgery. Conference paper. EasyChair. 2017. S. 51–53
Müller, Dominic, Bernd Heinlein, and Dario Denzler. 2017. “Application Specific Adaption of a Numerical Based Surgical Process.” Conference paper. In CAOS International 2017, 17th Annual Meeting of the International Society for Computer Assisted Orthopaedic Surgery, 51–53. EasyChair. https://doi.org/10.21256/zhaw-3348.
Müller, Dominic, et al. “Application Specific Adaption of a Numerical Based Surgical Process.” CAOS International 2017, 17th Annual Meeting of the International Society for Computer Assisted Orthopaedic Surgery, EasyChair, 2017, pp. 51–53, https://doi.org/10.21256/zhaw-3348.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.