Publikationstyp: Beitrag in wissenschaftlicher Zeitschrift
Art der Begutachtung: Peer review (Publikation)
Titel: Broadly tunable mid-infrared VECSEL for multiple components hydrocarbon gas sensing
Autor/-in: Rey, Julien
Fill, M.
Felder, F.
Sigrist, M. W.
DOI: 10.1007/s00340-014-5911-1
Erschienen in: Applied Physics B
Band(Heft): 117
Heft: 3
Seite(n): 935
Seiten bis: 939
Erscheinungsdatum: 2014
Verlag / Hrsg. Institution: Springer
ISSN: 0946-2171
1432-0649
Sprache: Englisch
Fachgebiet (DDC): 530: Physik
Zusammenfassung: A new sensing platform to simultaneously identify and quantify volatile C1 to C4 alkanes in multi-component gas mixtures is presented. This setup is based on an optically pumped, broadly tunable mid-infrared vertical-external-cavity surface-emitting laser (VECSEL) developed for gas detection. The lead-chalcogenide VECSEL is the key component of the presented optical sensor. The potential of the proposed sensing setup is illustrated by experimental absorption spectra obtained from various mixtures of volatile hydrocarbons and water vapor. The sensor has a sub-ppm limit of detection for each targeted alkane in a hydrocarbon gas mixture even in the presence of a high water vapor content.
URI: https://digitalcollection.zhaw.ch/handle/11475/15842
Volltext Version: Publizierte Version
Lizenz (gemäss Verlagsvertrag): Lizenz gemäss Verlagsvertrag
Departement: School of Engineering
Organisationseinheit: Institut für Angewandte Mathematik und Physik (IAMP)
Enthalten in den Sammlungen:Publikationen School of Engineering

Dateien zu dieser Ressource:
Es gibt keine Dateien zu dieser Ressource.
Zur Langanzeige
Rey, J., Fill, M., Felder, F., & Sigrist, M. W. (2014). Broadly tunable mid-infrared VECSEL for multiple components hydrocarbon gas sensing. Applied Physics B, 117(3), 935–939. https://doi.org/10.1007/s00340-014-5911-1
Rey, J. et al. (2014) ‘Broadly tunable mid-infrared VECSEL for multiple components hydrocarbon gas sensing’, Applied Physics B, 117(3), pp. 935–939. Available at: https://doi.org/10.1007/s00340-014-5911-1.
J. Rey, M. Fill, F. Felder, and M. W. Sigrist, “Broadly tunable mid-infrared VECSEL for multiple components hydrocarbon gas sensing,” Applied Physics B, vol. 117, no. 3, pp. 935–939, 2014, doi: 10.1007/s00340-014-5911-1.
REY, Julien, M. FILL, F. FELDER und M. W. SIGRIST, 2014. Broadly tunable mid-infrared VECSEL for multiple components hydrocarbon gas sensing. Applied Physics B. 2014. Bd. 117, Nr. 3, S. 935–939. DOI 10.1007/s00340-014-5911-1
Rey, Julien, M. Fill, F. Felder, and M. W. Sigrist. 2014. “Broadly Tunable Mid-Infrared VECSEL for Multiple Components Hydrocarbon Gas Sensing.” Applied Physics B 117 (3): 935–39. https://doi.org/10.1007/s00340-014-5911-1.
Rey, Julien, et al. “Broadly Tunable Mid-Infrared VECSEL for Multiple Components Hydrocarbon Gas Sensing.” Applied Physics B, vol. 117, no. 3, 2014, pp. 935–39, https://doi.org/10.1007/s00340-014-5911-1.


Alle Ressourcen in diesem Repository sind urheberrechtlich geschützt, soweit nicht anderweitig angezeigt.