Full metadata record
DC FieldValueLanguage
dc.contributor.authorBauer, Christoph-
dc.contributor.authorGröger, Ines-
dc.contributor.authorRupprecht, Roland-
dc.contributor.authorGaßmann, Karl Günter-
dc.date.accessioned2018-08-09T12:18:28Z-
dc.date.available2018-08-09T12:18:28Z-
dc.date.issued2008-10-
dc.identifier.issn0003-9993de_CH
dc.identifier.issn1532-821Xde_CH
dc.identifier.urihttps://digitalcollection.zhaw.ch/handle/11475/8922-
dc.description.abstractObjective: To investigate the intrasession reliability of center of pressure (COP) parameters calculated from force platform measurements. Design: A cross-sectional study. Setting: Gait and balance laboratory. Participants: Community-dwelling healthy older adults (N=63) above the age of 62 years (mean age, 78.74y). Interventions: Not applicable. Main Outcome Measures: COP was estimated from a force platform, and the following parameters were calculated: (1) the total length of the COP displacement, (2) area of sway, (3) length of the COP displacement in the sagittal plane, and (4) length of the COP displacement in the frontal plane. Intraclass correlation coefficients (ICCs) were calculated by using 3 successive trials with 4 different test conditions. The test conditions were (1) normative standing with eyes open, (2) normative standing with eyes closed, (3) narrow stance with eyes open, and (4) narrow stance with eyes closed. Results: The ICCs for the tests with eyes closed (0.710-0.946) were higher than those for tests with eyes open (0.841-0.945). The highest value was obtained for the vector sum of the COP during anteroposterior movement in narrow stance with eyes closed (0.946). The value .710 was the lowest of all parameters and was an outlier for the narrow stance with eyes closed test, which was otherwise very reliable. Conclusions: Eight of 16 calculated ICCs showed excellent reliability (>0.90). They can be recommended for further use in clinical trials. Tests with closed eyes were more reliable than tests with eyes open. We recommend using eyes closed test conditions when assessing static balance control. For these tests, all the calculated ICCs were over 0.90, except for measurements of sway area.de_CH
dc.language.isoende_CH
dc.publisherElsevierde_CH
dc.relation.ispartofArchives of Physical Medicine and Rehabilitationde_CH
dc.rightsLicence according to publishing contractde_CH
dc.subjectAgedde_CH
dc.subjectAgingde_CH
dc.subjectAnalysis of Variancede_CH
dc.subjectCross-Sectional Studiesde_CH
dc.subjectFemalede_CH
dc.subjectHumansde_CH
dc.subjectMalede_CH
dc.subjectMiddle Agedde_CH
dc.subjectPostural Balancede_CH
dc.subjectPosturede_CH
dc.subjectPressurede_CH
dc.subjectProprioceptionde_CH
dc.subjectReproducibility of Resultsde_CH
dc.subjectVision, Ocularde_CH
dc.subject.ddc305: Personengruppen (Alter, Herkunft, Geschlecht, Einkommen)de_CH
dc.subject.ddc610: Medizin und Gesundheitde_CH
dc.titleIntrasession reliability of force platform parameters in community-dwelling older adultsde_CH
dc.typeBeitrag in wissenschaftlicher Zeitschriftde_CH
dcterms.typeTextde_CH
zhaw.departementGesundheitde_CH
dc.identifier.doi10.1016/j.apmr.2008.02.033de_CH
dc.identifier.pmid18929026de_CH
zhaw.funding.euNode_CH
zhaw.issue10de_CH
zhaw.originated.zhawYesde_CH
zhaw.pages.end1982de_CH
zhaw.pages.start1977de_CH
zhaw.publication.statuspublishedVersionde_CH
zhaw.volume89de_CH
zhaw.publication.reviewPeer review (Publikation)de_CH
zhaw.webfeedAngewandte Gerontologiede_CH
Appears in collections:Publikationen Gesundheit

Files in This Item:
There are no files associated with this item.
Show simple item record
Bauer, C., Gröger, I., Rupprecht, R., & Gaßmann, K. G. (2008). Intrasession reliability of force platform parameters in community-dwelling older adults. Archives of Physical Medicine and Rehabilitation, 89(10), 1977–1982. https://doi.org/10.1016/j.apmr.2008.02.033
Bauer, C. et al. (2008) ‘Intrasession reliability of force platform parameters in community-dwelling older adults’, Archives of Physical Medicine and Rehabilitation, 89(10), pp. 1977–1982. Available at: https://doi.org/10.1016/j.apmr.2008.02.033.
C. Bauer, I. Gröger, R. Rupprecht, and K. G. Gaßmann, “Intrasession reliability of force platform parameters in community-dwelling older adults,” Archives of Physical Medicine and Rehabilitation, vol. 89, no. 10, pp. 1977–1982, Oct. 2008, doi: 10.1016/j.apmr.2008.02.033.
BAUER, Christoph, Ines GRÖGER, Roland RUPPRECHT und Karl Günter GASSMANN, 2008. Intrasession reliability of force platform parameters in community-dwelling older adults. Archives of Physical Medicine and Rehabilitation. Oktober 2008. Bd. 89, Nr. 10, S. 1977–1982. DOI 10.1016/j.apmr.2008.02.033
Bauer, Christoph, Ines Gröger, Roland Rupprecht, and Karl Günter Gaßmann. 2008. “Intrasession Reliability of Force Platform Parameters in Community-Dwelling Older Adults.” Archives of Physical Medicine and Rehabilitation 89 (10): 1977–82. https://doi.org/10.1016/j.apmr.2008.02.033.
Bauer, Christoph, et al. “Intrasession Reliability of Force Platform Parameters in Community-Dwelling Older Adults.” Archives of Physical Medicine and Rehabilitation, vol. 89, no. 10, Oct. 2008, pp. 1977–82, https://doi.org/10.1016/j.apmr.2008.02.033.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.