Titel: Engineering characteristics of a single-use stirred bioreactor at benchtop scale : the Mobius CellReady 3 L bioreactor as case study
Autor/-in: Kaiser, Stephan
Eibl-Schindler, Regine
Eibl, Dieter
DOI: 10.1002/elsc.201000171
Erschienen in: Engineering in Life Sciences
Band(Heft): 11
Heft: 4
Seite(n): 359
Seiten bis: 368
Erscheinungsdatum: Aug-2011
Verlag / Hrsg. Institution: Wiley
Verlag / Hrsg. Institution: Weinheim
ISSN: 1618-0240
1618-2863
Sprache: Englisch
Fachgebiet (DDC): 660: Technische Chemie
Zusammenfassung: Stirred single-use bioreactors can be used as substitutes for their conventional counterparts made of glass or stainless steel in the development and production of biopharmaceuticals wherever possible. Various studies have confirmed their comparability in cell growth as well as in product quantity and quality. However, information about their engineering characteristics is still rare. This study focuses on the stirred Mobius® CellReady 3L bioreactor. The main engineering parameters for typical operation conditions used in animal cell cultivations are presented for the first time. Numerical simulations with a commercial CFD package (Fluent 6.3) were accomplished to obtain data on the single- and multi-phase fluid flow, power input, mixing time and oxygen mass transfer. The results, which were compared with data from experiments and from the literature, reveal the suitability of the Mobius® CellReady 3L bioreactor for cell expansion and protein production with animal cell cultures. Furthermore, the data enable comparisons with other single-use and reusable cell culture bioreactors at bench-scale.
URI: https://digitalcollection.zhaw.ch/handle/11475/2318
Volltext Version: Publizierte Version
Lizenz (gemäss Verlagsvertrag): Lizenz gemäss Verlagsvertrag
Departement: Life Sciences und Facility Management
Organisationseinheit: Institut für Chemie und Biotechnologie (ICBT)
Enthalten in den Sammlungen:Publikationen Life Sciences und Facility Management

Dateien zu dieser Ressource:
Es gibt keine Dateien zu dieser Ressource.
Zur Langanzeige
Kaiser, S., Eibl-Schindler, R., & Eibl, D. (2011). Engineering characteristics of a single-use stirred bioreactor at benchtop scale : the Mobius CellReady 3 L bioreactor as case study. Engineering in Life Sciences, 11(4), 359–368. https://doi.org/10.1002/elsc.201000171
Kaiser, S., Eibl-Schindler, R. and Eibl, D. (2011) ‘Engineering characteristics of a single-use stirred bioreactor at benchtop scale : the Mobius CellReady 3 L bioreactor as case study’, Engineering in Life Sciences, 11(4), pp. 359–368. Available at: https://doi.org/10.1002/elsc.201000171.
S. Kaiser, R. Eibl-Schindler, and D. Eibl, “Engineering characteristics of a single-use stirred bioreactor at benchtop scale : the Mobius CellReady 3 L bioreactor as case study,” Engineering in Life Sciences, vol. 11, no. 4, pp. 359–368, Aug. 2011, doi: 10.1002/elsc.201000171.
KAISER, Stephan, Regine EIBL-SCHINDLER und Dieter EIBL, 2011. Engineering characteristics of a single-use stirred bioreactor at benchtop scale : the Mobius CellReady 3 L bioreactor as case study. Engineering in Life Sciences. August 2011. Bd. 11, Nr. 4, S. 359–368. DOI 10.1002/elsc.201000171
Kaiser, Stephan, Regine Eibl-Schindler, and Dieter Eibl. 2011. “Engineering Characteristics of a Single-Use Stirred Bioreactor at Benchtop Scale : The Mobius CellReady 3 L Bioreactor as Case Study.” Engineering in Life Sciences 11 (4): 359–68. https://doi.org/10.1002/elsc.201000171.
Kaiser, Stephan, et al. “Engineering Characteristics of a Single-Use Stirred Bioreactor at Benchtop Scale : The Mobius CellReady 3 L Bioreactor as Case Study.” Engineering in Life Sciences, vol. 11, no. 4, Aug. 2011, pp. 359–68, https://doi.org/10.1002/elsc.201000171.


Alle Ressourcen in diesem Repository sind urheberrechtlich geschützt, soweit nicht anderweitig angezeigt.