Bitte benutzen Sie diese Kennung, um auf die Ressource zu verweisen: https://doi.org/10.21256/zhaw-1319
Publikationstyp: Konferenz: Paper
Art der Begutachtung: Keine Angabe
Titel: Field testing of portable led flasher for nominal power measurements of pv-modules on-site
Autor/-in: Knecht, Raphael
Baumgartner, Franz
Carigiet, Fabian
Frei, Christian
Beglinger, Fritz
Zaaiman, Willem
Pavanello, Diego
Field, Michael
Galleano, Roberto
Sample, Tony
DOI: 10.21256/zhaw-1319
Angaben zur Konferenz: 33rd European Photovoltaic Solar Energy Conference and Exhibition (EU PVSEC), Amsterdam, Netherlands, 25-29 September 2017
Erscheinungsdatum: 2017
Verlag / Hrsg. Institution: ZHAW Zürcher Hochschule für Angewandte Wissenschaften
Sprache: Englisch
Schlagwörter: PV Module; Electrical Properties; Qualification and Testing; Cost reduction; Degradation
Fachgebiet (DDC): 621.04: Energietechnik
Zusammenfassung: Nominal power measurements of individual PV modules are needed to quantify the critical modules of PV plants offering lower energy production than expected. Today’s state of the art procedure of shipping a small number of modules to a laboratory is time- and cost intensive and it bears the chance of accidental damage. The Portable LED Flasher (PLF) was developed to require no dismounting of the modules. The quality of the PLF was tested on three PV plants in Switzerland. Additionally, ten PV modules of each plant were measured in the certified indoor laboratory of SUPSI, resulting in a maximum deviation of 3% of the STC values. Furthermore, a round robin test on a single crystalline silicon reference module at 25°C was performed at the JRC’s ESTI laboratory, the Swiss Mobile Flasher Bus and SUPSI resulting in a maximum deviation of the mean values below 1% compared to the PLF. A throughput of up to 150 modules or 500 modules respectively per day is expected and the total measurement costs are estimated to be about a tenth of the costs compared to an indoor laboratory. Module temperature measurement is crucial for a low total uncertainty. Thus, methods such as pre-shadowing of the module and approximation of cell temperature are the current focus of further improvement of the PLF measurement method.
URI: https://digitalcollection.zhaw.ch/handle/11475/1356
Volltext Version: Publizierte Version
Lizenz (gemäss Verlagsvertrag): Keine Angabe
Departement: School of Engineering
Organisationseinheit: Institut für Energiesysteme und Fluid-Engineering (IEFE)
Enthalten in den Sammlungen:Publikationen School of Engineering

Dateien zu dieser Ressource:
Datei Beschreibung GrößeFormat 
6CO_15_1_paper.pdfPaper964.7 kBAdobe PDFMiniaturbild
Öffnen/Anzeigen
Zur Langanzeige
Knecht, R., Baumgartner, F., Carigiet, F., Frei, C., Beglinger, F., Zaaiman, W., Pavanello, D., Field, M., Galleano, R., & Sample, T. (2017). Field testing of portable led flasher for nominal power measurements of pv-modules on-site. 33rd European Photovoltaic Solar Energy Conference and Exhibition (EU PVSEC), Amsterdam, Netherlands, 25-29 September 2017. https://doi.org/10.21256/zhaw-1319
Knecht, R. et al. (2017) ‘Field testing of portable led flasher for nominal power measurements of pv-modules on-site’, in 33rd European Photovoltaic Solar Energy Conference and Exhibition (EU PVSEC), Amsterdam, Netherlands, 25-29 September 2017. ZHAW Zürcher Hochschule für Angewandte Wissenschaften. Available at: https://doi.org/10.21256/zhaw-1319.
R. Knecht et al., “Field testing of portable led flasher for nominal power measurements of pv-modules on-site,” in 33rd European Photovoltaic Solar Energy Conference and Exhibition (EU PVSEC), Amsterdam, Netherlands, 25-29 September 2017, 2017. doi: 10.21256/zhaw-1319.
KNECHT, Raphael, Franz BAUMGARTNER, Fabian CARIGIET, Christian FREI, Fritz BEGLINGER, Willem ZAAIMAN, Diego PAVANELLO, Michael FIELD, Roberto GALLEANO und Tony SAMPLE, 2017. Field testing of portable led flasher for nominal power measurements of pv-modules on-site. In: 33rd European Photovoltaic Solar Energy Conference and Exhibition (EU PVSEC), Amsterdam, Netherlands, 25-29 September 2017. Conference paper. ZHAW Zürcher Hochschule für Angewandte Wissenschaften. 2017
Knecht, Raphael, Franz Baumgartner, Fabian Carigiet, Christian Frei, Fritz Beglinger, Willem Zaaiman, Diego Pavanello, Michael Field, Roberto Galleano, and Tony Sample. 2017. “Field Testing of Portable Led Flasher for Nominal Power Measurements of Pv-Modules On-Site.” Conference paper. In 33rd European Photovoltaic Solar Energy Conference and Exhibition (EU PVSEC), Amsterdam, Netherlands, 25-29 September 2017. ZHAW Zürcher Hochschule für Angewandte Wissenschaften. https://doi.org/10.21256/zhaw-1319.
Knecht, Raphael, et al. “Field Testing of Portable Led Flasher for Nominal Power Measurements of Pv-Modules On-Site.” 33rd European Photovoltaic Solar Energy Conference and Exhibition (EU PVSEC), Amsterdam, Netherlands, 25-29 September 2017, ZHAW Zürcher Hochschule für Angewandte Wissenschaften, 2017, https://doi.org/10.21256/zhaw-1319.


Alle Ressourcen in diesem Repository sind urheberrechtlich geschützt, soweit nicht anderweitig angezeigt.