Full metadata record
DC FieldValueLanguage
dc.contributor.authorKuster, Roman-
dc.contributor.authorKellenberger-Züst, Marion-
dc.contributor.authorHeinlein, Bernd-
dc.contributor.authorBaumgartner, Daniel-
dc.date.accessioned2018-08-28T14:45:33Z-
dc.date.available2018-08-28T14:45:33Z-
dc.date.issued2016-07-
dc.identifier.urihttps://digitalcollection.zhaw.ch/handle/11475/9848-
dc.description.abstractShoulder mobility is an important clinical sign in the assessment of the shoulder joint. However, here is no gold standard measuring shoulder mobility in clinical practice. While some health care personnel use functional scales like the Constant-Murley, others use a portable goniometer, and scientists use advanced motion capture systems to measure the range of motion (ROM). Unfortunately, the Constant-Murley Scale tells nothing about the ROM as it analyses functional mobility. Although low-cost and quick to perform, a goniometer can only be used in the two dimensional area, needs trained personnel, and is related to a measurement error of 8°. Basically, visual estimation of the ROM results in the same error, but depends on the expertise of the examiner and the pain intensity of the patient. In contrast, advanced systems like X-ray machines, cinematography or Mocaps allow to analyse shoulder joint motion in the three dimensional area, resulting in a significantly smaller measurement error. However, they are time consuming, need highly trained personnel and an advanced laboratory equipment making them unsuitable for clinical use. A shoulder patient passes therefore several mobility measurement types in his course of therapy depending on the preference of his health care personnel. It would therefore be very attractive to have a low-cost, easy-to-use, three dimensional measuring device to asses shoulder mobility in applied settings. In addition, it would be very smart if anyone, even without preliminary knowledge in the field of shoulder measurements, could use this device intuitively. For this reason, smartphone applications (Apps) were developed. Since existing Apps need trained personnel, have no exercise instructions, or show incorrect measurements, the ZHAW developed a new therapy application (therapp®, available in German speaking AppStores®). The program uses the factory implemented gyroscope of the iPhone® to analyse three dimensional motions and shall allow the user to measure the own shoulder ROM without preliminary knowhow. The aim of the present study was to analyse usability of the App to identify barriers for successful application and to assess their importance regarding feasibility and ease of use. In addition, concurrent validity of therapp V-1.0.0 using an iPhone 4 versus a validated Mocap (Xsens® MVN Biomech Awinda) in an applied setting was analysed.de_CH
dc.language.isoende_CH
dc.rightsNot specifiedde_CH
dc.subject.ddc610: Medizin und Gesundheitde_CH
dc.titleUsability and validity of a novel smartphone application to measure shoulder range of motionde_CH
dc.typeKonferenz: Sonstigesde_CH
dcterms.typeTextde_CH
zhaw.departementSchool of Engineeringde_CH
zhaw.organisationalunitInstitut für Mechanische Systeme (IMES)de_CH
zhaw.conference.details11th Conference of the International Shoulder Group (ISG), Winterthur, 14-16 July 2016de_CH
zhaw.funding.euNode_CH
zhaw.originated.zhawYesde_CH
zhaw.publication.statuspublishedVersionde_CH
zhaw.publication.reviewPeer review (Abstract)de_CH
zhaw.funding.snf147110de_CH
Appears in collections:Publikationen School of Engineering

Files in This Item:
There are no files associated with this item.
Show simple item record
Kuster, R., Kellenberger-Züst, M., Heinlein, B., & Baumgartner, D. (2016, July). Usability and validity of a novel smartphone application to measure shoulder range of motion. 11th Conference of the International Shoulder Group (ISG), Winterthur, 14-16 July 2016.
Kuster, R. et al. (2016) ‘Usability and validity of a novel smartphone application to measure shoulder range of motion’, in 11th Conference of the International Shoulder Group (ISG), Winterthur, 14-16 July 2016.
R. Kuster, M. Kellenberger-Züst, B. Heinlein, and D. Baumgartner, “Usability and validity of a novel smartphone application to measure shoulder range of motion,” in 11th Conference of the International Shoulder Group (ISG), Winterthur, 14-16 July 2016, Jul. 2016.
KUSTER, Roman, Marion KELLENBERGER-ZÜST, Bernd HEINLEIN und Daniel BAUMGARTNER, 2016. Usability and validity of a novel smartphone application to measure shoulder range of motion. In: 11th Conference of the International Shoulder Group (ISG), Winterthur, 14-16 July 2016. Conference presentation. Juli 2016
Kuster, Roman, Marion Kellenberger-Züst, Bernd Heinlein, and Daniel Baumgartner. 2016. “Usability and Validity of a Novel Smartphone Application to Measure Shoulder Range of Motion.” Conference presentation. In 11th Conference of the International Shoulder Group (ISG), Winterthur, 14-16 July 2016.
Kuster, Roman, et al. “Usability and Validity of a Novel Smartphone Application to Measure Shoulder Range of Motion.” 11th Conference of the International Shoulder Group (ISG), Winterthur, 14-16 July 2016, 2016.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.