Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Bastkowski, Frank | - |
dc.contributor.author | Spitzer, Petra | - |
dc.contributor.author | Eberhardt, Ralf | - |
dc.contributor.author | Adel, Beatrice | - |
dc.contributor.author | Wunderli, Samuel | - |
dc.contributor.author | Berdat, Daniel | - |
dc.contributor.author | Andres, Hanspeter | - |
dc.contributor.author | Brunschwig, Olivier | - |
dc.contributor.author | Máriássy, Michal | - |
dc.contributor.author | Fehér, Roger | - |
dc.contributor.author | Demuth, Caspar | - |
dc.contributor.author | Gonzaga, Fabiano Barbieri | - |
dc.contributor.author | Borges, Paulo Paschoal | - |
dc.contributor.author | da Silva Junior, Wiler Batista | - |
dc.contributor.author | Vospělová, Alena | - |
dc.contributor.author | Vičarová, Martina | - |
dc.contributor.author | Srithongtim, Sirinapha | - |
dc.date.accessioned | 2018-08-24T09:25:21Z | - |
dc.date.available | 2018-08-24T09:25:21Z | - |
dc.date.issued | 2013-12-23 | - |
dc.identifier.issn | 0949-1775 | de_CH |
dc.identifier.issn | 1432-0517 | de_CH |
dc.identifier.uri | https://digitalcollection.zhaw.ch/handle/11475/9580 | - |
dc.description.abstract | Metrological comparability as well as reliability of ion activity results measured with ion-selective electrodes (ISE) was investigated within the framework of an interlaboratory comparison between eight partners from national metrology institutes and expert laboratories. Two electrolyte solutions containing the clinically most relevant ions sodium, potassium, magnesium, calcium and chloride having ion activities near the physiological range served as samples. The calibration of the measurement set-ups of the participants was carried out using gravimetrically prepared aqueous electrolyte solutions. The ion activities of these calibration standards were calculated by means of the semiempirical Pitzer model. The measurement uncertainty of the measurement results was calculated according to the guide to the expression of uncertainty in measurement, GUM. Based on a new scale for ion activities traceable to the SI system of units, comparability and reliability of ISE measurement results of clinically relevant ions is realised. | de_CH |
dc.language.iso | en | de_CH |
dc.publisher | Springer | de_CH |
dc.relation.ispartof | Accreditation and Quality Assurance | de_CH |
dc.rights | Licence according to publishing contract | de_CH |
dc.subject.ddc | 610: Medizin und Gesundheit | de_CH |
dc.title | Pitzer ion activities in mixed electrolytes for calibration of ion-selective electrodes used in clinical chemistry | de_CH |
dc.type | Beitrag in wissenschaftlicher Zeitschrift | de_CH |
dcterms.type | Text | de_CH |
zhaw.departement | Life Sciences und Facility Management | de_CH |
zhaw.organisationalunit | Institut für Chemie und Biotechnologie (ICBT) | de_CH |
dc.identifier.doi | 10.1007/s00769-013-1016-5 | de_CH |
zhaw.funding.eu | No | de_CH |
zhaw.issue | 6 | de_CH |
zhaw.originated.zhaw | Yes | de_CH |
zhaw.pages.end | 479 | de_CH |
zhaw.pages.start | 469 | de_CH |
zhaw.publication.status | publishedVersion | de_CH |
zhaw.volume | 18 | de_CH |
zhaw.publication.review | Peer review (Publikation) | de_CH |
Appears in collections: | Publikationen Life Sciences und Facility Management |
Files in This Item:
There are no files associated with this item.
Show simple item record
Bastkowski, F., Spitzer, P., Eberhardt, R., Adel, B., Wunderli, S., Berdat, D., Andres, H., Brunschwig, O., Máriássy, M., Fehér, R., Demuth, C., Gonzaga, F. B., Borges, P. P., da Silva Junior, W. B., Vospělová, A., Vičarová, M., & Srithongtim, S. (2013). Pitzer ion activities in mixed electrolytes for calibration of ion-selective electrodes used in clinical chemistry. Accreditation and Quality Assurance, 18(6), 469–479. https://doi.org/10.1007/s00769-013-1016-5
Bastkowski, F. et al. (2013) ‘Pitzer ion activities in mixed electrolytes for calibration of ion-selective electrodes used in clinical chemistry’, Accreditation and Quality Assurance, 18(6), pp. 469–479. Available at: https://doi.org/10.1007/s00769-013-1016-5.
F. Bastkowski et al., “Pitzer ion activities in mixed electrolytes for calibration of ion-selective electrodes used in clinical chemistry,” Accreditation and Quality Assurance, vol. 18, no. 6, pp. 469–479, Dec. 2013, doi: 10.1007/s00769-013-1016-5.
BASTKOWSKI, Frank, Petra SPITZER, Ralf EBERHARDT, Beatrice ADEL, Samuel WUNDERLI, Daniel BERDAT, Hanspeter ANDRES, Olivier BRUNSCHWIG, Michal MÁRIÁSSY, Roger FEHÉR, Caspar DEMUTH, Fabiano Barbieri GONZAGA, Paulo Paschoal BORGES, Wiler Batista DA SILVA JUNIOR, Alena VOSPĚLOVÁ, Martina VIČAROVÁ und Sirinapha SRITHONGTIM, 2013. Pitzer ion activities in mixed electrolytes for calibration of ion-selective electrodes used in clinical chemistry. Accreditation and Quality Assurance. 23 Dezember 2013. Bd. 18, Nr. 6, S. 469–479. DOI 10.1007/s00769-013-1016-5
Bastkowski, Frank, Petra Spitzer, Ralf Eberhardt, Beatrice Adel, Samuel Wunderli, Daniel Berdat, Hanspeter Andres, et al. 2013. “Pitzer Ion Activities in Mixed Electrolytes for Calibration of Ion-Selective Electrodes Used in Clinical Chemistry.” Accreditation and Quality Assurance 18 (6): 469–79. https://doi.org/10.1007/s00769-013-1016-5.
Bastkowski, Frank, et al. “Pitzer Ion Activities in Mixed Electrolytes for Calibration of Ion-Selective Electrodes Used in Clinical Chemistry.” Accreditation and Quality Assurance, vol. 18, no. 6, Dec. 2013, pp. 469–79, https://doi.org/10.1007/s00769-013-1016-5.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.