Title: | Construct validity of change scores of the Chair Stand Test versus Timed Up and Go test, KOOS questionnaire and the isometric muscle strength test in patients with severe knee osteoarthritis undergoing total knee replacement |
Authors: | Huber, Erika Meichtry, André de Bie, Rob A. Bastiaenen, Caroline H. |
DOI: | 10.1016/j.math.2015.09.012 |
Published in: | Manual Therapy |
Volume(Issue): | 21 |
Page(s): | 262 |
Pages to: | 267 |
Issue Date: | 2016 |
Publisher / Ed. Institution: | Elsevier |
ISSN: | 1356-689X 1532-2769 |
Language: | English |
Subjects: | Chair stand test; Responsiveness; Longitudinal validity; Knee osteoarthritis; Total knee replacement |
Subject (DDC): | 615.82: Physical therapy 616.7: Diseases of musculoskeletal system and orthopaedics |
Abstract: | Introduction: The Chair Stand Test (CST) is a frequently used performance-based test in clinical studies involving individuals with knee osteoarthritis and demonstrates good reliability. Aim: To assess the construct validity of change scores of the CST compared to three other measures in patients before and after total knee replacement surgery. Methods: The construct validity of change scores of the CST compared to the Timed Up and Go (TUG) test, the Knee Injury and Osteoarthritis Outcome Score questionnaire (KOOS, subscale ADL) and the isometric muscle strength test of the knee extensors (IMS sum) was measured 1-2 week before and 3 months after surgery. Results: Change (%) CST = -4.45, TUG = -2.08, KOOS ADL = 43.90, IMS sum = -13.24. Correlations CST–TUG = 0.56 (95% confidence interval (CI) 0.29, 0.74), CST–KOOS = -0.31 (95% CI -0.57, 0.01), CST–IMS sum = -0.11 (95% CI -0.42, 0.22). Comparison of pairwise correlations: CST–KOOS versus CST–TUG (p < 0.0004), CST–TUG versus CST–IMS sum (p < 0.0068), CST–KOOS versus CST–IMS sum (p < 0.3100). Conclusion: For patients undergoing TKR, the CST might not be an ideal measure to assess change between pre-surgery and 3 months post-surgery. Construct validity of change scores was close to zero but the result might have been influenced by the relatively small homogeneous sample size and the chosen timespan of measurement. We ordered pairwise correlations based on the strength of correlation between the different instruments, which to our knowledge has never been done before. |
URI: | https://digitalcollection.zhaw.ch/handle/11475/8300 |
Fulltext version: | Published version |
License (according to publishing contract): | Licence according to publishing contract |
Departement: | School of Health Sciences |
Organisational Unit: | Institute of Physiotherapy (IPT) |
Appears in collections: | Publikationen Gesundheit |
Files in This Item:
There are no files associated with this item.
Show full item record
Huber, E., Meichtry, A., de Bie, R. A., & Bastiaenen, C. H. (2016). Construct validity of change scores of the Chair Stand Test versus Timed Up and Go test, KOOS questionnaire and the isometric muscle strength test in patients with severe knee osteoarthritis undergoing total knee replacement. Manual Therapy, 21, 262–267. https://doi.org/10.1016/j.math.2015.09.012
Huber, E. et al. (2016) ‘Construct validity of change scores of the Chair Stand Test versus Timed Up and Go test, KOOS questionnaire and the isometric muscle strength test in patients with severe knee osteoarthritis undergoing total knee replacement’, Manual Therapy, 21, pp. 262–267. Available at: https://doi.org/10.1016/j.math.2015.09.012.
E. Huber, A. Meichtry, R. A. de Bie, and C. H. Bastiaenen, “Construct validity of change scores of the Chair Stand Test versus Timed Up and Go test, KOOS questionnaire and the isometric muscle strength test in patients with severe knee osteoarthritis undergoing total knee replacement,” Manual Therapy, vol. 21, pp. 262–267, 2016, doi: 10.1016/j.math.2015.09.012.
HUBER, Erika, André MEICHTRY, Rob A. DE BIE und Caroline H. BASTIAENEN, 2016. Construct validity of change scores of the Chair Stand Test versus Timed Up and Go test, KOOS questionnaire and the isometric muscle strength test in patients with severe knee osteoarthritis undergoing total knee replacement. Manual Therapy. 2016. Bd. 21, S. 262–267. DOI 10.1016/j.math.2015.09.012
Huber, Erika, André Meichtry, Rob A. de Bie, and Caroline H. Bastiaenen. 2016. “Construct Validity of Change Scores of the Chair Stand Test versus Timed up and Go Test, KOOS Questionnaire and the Isometric Muscle Strength Test in Patients with Severe Knee Osteoarthritis Undergoing Total Knee Replacement.” Manual Therapy 21: 262–67. https://doi.org/10.1016/j.math.2015.09.012.
Huber, Erika, et al. “Construct Validity of Change Scores of the Chair Stand Test versus Timed up and Go Test, KOOS Questionnaire and the Isometric Muscle Strength Test in Patients with Severe Knee Osteoarthritis Undergoing Total Knee Replacement.” Manual Therapy, vol. 21, 2016, pp. 262–67, https://doi.org/10.1016/j.math.2015.09.012.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.