Publication type: | Article in scientific journal |
Type of review: | Peer review (publication) |
Title: | Intertester and intratester reliability of a movement control test battery for patients with knee osteoarthritis and controls |
Authors: | Kaukinen, P.T. Arokoski, J.P. Huber, E.O. Luomajoki, H.A. |
Published in: | Journal of Musculoskeletal & Neuronal Interactions |
Volume(Issue): | 17 |
Issue: | 3 |
Page(s): | 197 |
Pages to: | 208 |
Issue Date: | 2017 |
Publisher / Ed. Institution: | The International Society of Musculoskeletal and Neuronal Interactions |
Publisher / Ed. Institution: | Griechenland |
ISSN: | 1108-7161 |
Language: | English |
Subjects: | Movement control; Reliability; Knee osteoarthritis |
Subject (DDC): | 615.82: Physical therapy 616.7: Diseases of musculoskeletal system and orthopaedics |
Abstract: | Objectives: To develop a test battery of movement control (MC) tests and assess its intertester and intratester reliability. Methods: 29 subjects with knee OA with mean age of 64.7 (SD 8.7) years and 12 controls without either knee pain or previous diagnosis of OA (mean age 36.6 (SD 16.2) years) were included. Two experienced physiotherapists rated the filmed test performance of six MC tests blinded to the patients and to each other on 3-point scale as correct, incorrect or failed. Weighted kappa coefficient (wK) with 95% confidence interval (95%CI) and the percentage of agreement were calculated for each test. Results: One-leg stance, one-leg squat 30 degrees and step down tests showed moderate to excellent inter- and intratester reliability with wK ranging between 0.43-0.85 for intertester and 0.51-0.80 for intratester reliability. The reliability of the 90 degrees squat test, small squat and step up tests was poor (wK ranging between 0.09-0.50). Conclusions: One-leg stance test, one-leg squat 30 degrees and step down test are reliable in the subjects with knee OA and controls. Further studies are needed to evaluate the discriminative validity of the reliable tests. |
URI: | http://www.ismni.org/jmni/pdf/69/jmni_17_197.pdf https://digitalcollection.zhaw.ch/handle/11475/8249 |
Fulltext version: | Published version |
License (according to publishing contract): | Licence according to publishing contract |
Departement: | School of Health Sciences |
Organisational Unit: | Institute of Physiotherapy (IPT) |
Appears in collections: | Publikationen Gesundheit |
Files in This Item:
There are no files associated with this item.
Show full item record
Kaukinen, P. T., Arokoski, J. P., Huber, E. O., & Luomajoki, H. A. (2017). Intertester and intratester reliability of a movement control test battery for patients with knee osteoarthritis and controls. Journal of Musculoskeletal & Neuronal Interactions, 17(3), 197–208. http://www.ismni.org/jmni/pdf/69/jmni_17_197.pdf
Kaukinen, P.T. et al. (2017) ‘Intertester and intratester reliability of a movement control test battery for patients with knee osteoarthritis and controls’, Journal of Musculoskeletal & Neuronal Interactions, 17(3), pp. 197–208. Available at: http://www.ismni.org/jmni/pdf/69/jmni_17_197.pdf.
P. T. Kaukinen, J. P. Arokoski, E. O. Huber, and H. A. Luomajoki, “Intertester and intratester reliability of a movement control test battery for patients with knee osteoarthritis and controls,” Journal of Musculoskeletal & Neuronal Interactions, vol. 17, no. 3, pp. 197–208, 2017, [Online]. Available: http://www.ismni.org/jmni/pdf/69/jmni_17_197.pdf
KAUKINEN, P.T., J.P. AROKOSKI, E.O. HUBER und H.A. LUOMAJOKI, 2017. Intertester and intratester reliability of a movement control test battery for patients with knee osteoarthritis and controls. Journal of Musculoskeletal & Neuronal Interactions [online]. 2017. Bd. 17, Nr. 3, S. 197–208. Verfügbar unter: http://www.ismni.org/jmni/pdf/69/jmni_17_197.pdf
Kaukinen, P.T., J.P. Arokoski, E.O. Huber, and H.A. Luomajoki. 2017. “Intertester and Intratester Reliability of a Movement Control Test Battery for Patients with Knee Osteoarthritis and Controls.” Journal of Musculoskeletal & Neuronal Interactions 17 (3): 197–208. http://www.ismni.org/jmni/pdf/69/jmni_17_197.pdf.
Kaukinen, P. T., et al. “Intertester and Intratester Reliability of a Movement Control Test Battery for Patients with Knee Osteoarthritis and Controls.” Journal of Musculoskeletal & Neuronal Interactions, vol. 17, no. 3, 2017, pp. 197–208, http://www.ismni.org/jmni/pdf/69/jmni_17_197.pdf.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.