Please use this identifier to cite or link to this item:
https://doi.org/10.21256/zhaw-3571
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Sommer, Christian | - |
dc.contributor.author | Icken, Niels | - |
dc.contributor.author | Özden, Ismail | - |
dc.contributor.author | Lutters, Gerd | - |
dc.contributor.author | Scheidegger, Stephan | - |
dc.date.accessioned | 2018-04-04T11:43:01Z | - |
dc.date.available | 2018-04-04T11:43:01Z | - |
dc.date.issued | 2017 | - |
dc.identifier.issn | 2364-5504 | de_CH |
dc.identifier.uri | https://digitalcollection.zhaw.ch/handle/11475/4711 | - |
dc.language.iso | en | de_CH |
dc.publisher | De Gruyter | de_CH |
dc.relation.ispartof | Current Directions in Biomedical Engineering | de_CH |
dc.rights | http://creativecommons.org/licenses/by-nc-nd/4.0/ | de_CH |
dc.subject | Contrast Difference Curve | de_CH |
dc.subject | Image quality | de_CH |
dc.subject | Computer Tomography | de_CH |
dc.subject.ddc | 616: Innere Medizin und Krankheiten | de_CH |
dc.title | Evaluation of low contrast resolution and radiation dose in abdominal CT protocols by a difference detail curve (DDC) method | de_CH |
dc.type | Beitrag in wissenschaftlicher Zeitschrift | de_CH |
dcterms.type | Text | de_CH |
zhaw.departement | School of Engineering | de_CH |
zhaw.organisationalunit | Institut für Angewandte Mathematik und Physik (IAMP) | de_CH |
dc.identifier.doi | 10.21256/zhaw-3571 | - |
dc.identifier.doi | 10.1515/cdbme-2017-0109 | de_CH |
zhaw.funding.eu | No | de_CH |
zhaw.issue | 2 | de_CH |
zhaw.originated.zhaw | Yes | de_CH |
zhaw.pages.end | 519 | de_CH |
zhaw.pages.start | 517 | de_CH |
zhaw.publication.status | publishedVersion | de_CH |
zhaw.volume | 3 | de_CH |
zhaw.publication.review | Peer review (Publikation) | de_CH |
Appears in collections: | Publikationen School of Engineering |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
10.1515cdbme-2017-0109.pdf | 467.55 kB | Adobe PDF | View/Open |
Show simple item record
Sommer, C., Icken, N., Özden, I., Lutters, G., & Scheidegger, S. (2017). Evaluation of low contrast resolution and radiation dose in abdominal CT protocols by a difference detail curve (DDC) method. Current Directions in Biomedical Engineering, 3(2), 517–519. https://doi.org/10.21256/zhaw-3571
Sommer, C. et al. (2017) ‘Evaluation of low contrast resolution and radiation dose in abdominal CT protocols by a difference detail curve (DDC) method’, Current Directions in Biomedical Engineering, 3(2), pp. 517–519. Available at: https://doi.org/10.21256/zhaw-3571.
C. Sommer, N. Icken, I. Özden, G. Lutters, and S. Scheidegger, “Evaluation of low contrast resolution and radiation dose in abdominal CT protocols by a difference detail curve (DDC) method,” Current Directions in Biomedical Engineering, vol. 3, no. 2, pp. 517–519, 2017, doi: 10.21256/zhaw-3571.
SOMMER, Christian, Niels ICKEN, Ismail ÖZDEN, Gerd LUTTERS und Stephan SCHEIDEGGER, 2017. Evaluation of low contrast resolution and radiation dose in abdominal CT protocols by a difference detail curve (DDC) method. Current Directions in Biomedical Engineering. 2017. Bd. 3, Nr. 2, S. 517–519. DOI 10.21256/zhaw-3571
Sommer, Christian, Niels Icken, Ismail Özden, Gerd Lutters, and Stephan Scheidegger. 2017. “Evaluation of Low Contrast Resolution and Radiation Dose in Abdominal CT Protocols by a Difference Detail Curve (DDC) Method.” Current Directions in Biomedical Engineering 3 (2): 517–19. https://doi.org/10.21256/zhaw-3571.
Sommer, Christian, et al. “Evaluation of Low Contrast Resolution and Radiation Dose in Abdominal CT Protocols by a Difference Detail Curve (DDC) Method.” Current Directions in Biomedical Engineering, vol. 3, no. 2, 2017, pp. 517–19, https://doi.org/10.21256/zhaw-3571.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.