Publikationstyp: Konferenz: Paper
Art der Begutachtung: Keine Angabe
Titel: Comparison of image quality between a digital panorama X-ray unit with a CdTe-CMOS detector and panorama Xray units with other types of digital detectors
Autor/-in: Scheidegger, Stephan
Tagungsband: SSRMP Annual Scientific Meeting 2009 : University Hospital Basel 19th and 20th of November 2009: Abstracts & Proceedings
Seite(n): 63
Seiten bis: 69
Angaben zur Konferenz: Annual Scientific Meeting 2009 der Schweizerischen Gesellschaft für Strahlenbiologie und Medizinische Physik (SSRMP), Basel, 19-20 November 2009
Erscheinungsdatum: 2009
Verlag / Hrsg. Institution: SSRMP/DGMP/ÖGMP
Verlag / Hrsg. Institution: Basel
ISBN: 3-908-125-49-9
Sprache: Englisch
Schlagwörter: CDTE-CMOS; Digital detector; Panorama x-ray unit
Fachgebiet (DDC): 530: Physik
616: Innere Medizin und Krankheiten
Zusammenfassung: An investigation of the image quality of 5 panoramic X-ray units was carried out for this paper. Measurement of the MTF clearly shows good resolution for the Art Plus unit (MTF(50%) = 5.61 lp / mm) compared to the average of all 5 of the units (3.44 ± 1.55 lp /mm). To investigate image noise, the ratio was calculated between average gray scale value and standard deviation in a 32 × 32 matrix (R32x32). Compared to the other units, identical regions in the image are less noisy for the Art Plus unit (32x32 R = 92.28 and 32x32 R = 19.40 ± 11.00 for the other units). Also image displacement of a series of images was determined for the Art Plus and the Pro Max unit. The displacements were between 1-5 Pixels for both.
URI: http://www.ssrpm.ch/old/2009/proceedings-2009.pdf
https://digitalcollection.zhaw.ch/handle/11475/3559
Volltext Version: Publizierte Version
Lizenz (gemäss Verlagsvertrag): Lizenz gemäss Verlagsvertrag
Departement: School of Engineering
Enthalten in den Sammlungen:Publikationen School of Engineering

Dateien zu dieser Ressource:
Es gibt keine Dateien zu dieser Ressource.
Zur Langanzeige
Scheidegger, S. (2009). Comparison of image quality between a digital panorama X-ray unit with a CdTe-CMOS detector and panorama Xray units with other types of digital detectors [Conference paper]. SSRMP Annual Scientific Meeting 2009 : University Hospital Basel 19th and 20th of November 2009: Abstracts & Proceedings, 63–69. http://www.ssrpm.ch/old/2009/proceedings-2009.pdf
Scheidegger, S. (2009) ‘Comparison of image quality between a digital panorama X-ray unit with a CdTe-CMOS detector and panorama Xray units with other types of digital detectors’, in SSRMP Annual Scientific Meeting 2009 : University Hospital Basel 19th and 20th of November 2009: Abstracts & Proceedings. Basel: SSRMP/DGMP/ÖGMP, pp. 63–69. Available at: http://www.ssrpm.ch/old/2009/proceedings-2009.pdf.
S. Scheidegger, “Comparison of image quality between a digital panorama X-ray unit with a CdTe-CMOS detector and panorama Xray units with other types of digital detectors,” in SSRMP Annual Scientific Meeting 2009 : University Hospital Basel 19th and 20th of November 2009: Abstracts & Proceedings, 2009, pp. 63–69. [Online]. Available: http://www.ssrpm.ch/old/2009/proceedings-2009.pdf
SCHEIDEGGER, Stephan, 2009. Comparison of image quality between a digital panorama X-ray unit with a CdTe-CMOS detector and panorama Xray units with other types of digital detectors. In: SSRMP Annual Scientific Meeting 2009 : University Hospital Basel 19th and 20th of November 2009: Abstracts & Proceedings [online]. Conference paper. Basel: SSRMP/DGMP/ÖGMP. 2009. S. 63–69. ISBN 3-908-125-49-9. Verfügbar unter: http://www.ssrpm.ch/old/2009/proceedings-2009.pdf
Scheidegger, Stephan. 2009. “Comparison of Image Quality between a Digital Panorama X-Ray Unit with a CdTe-CMOS Detector and Panorama Xray Units with Other Types of Digital Detectors.” Conference paper. In SSRMP Annual Scientific Meeting 2009 : University Hospital Basel 19th and 20th of November 2009: Abstracts & Proceedings, 63–69. Basel: SSRMP/DGMP/ÖGMP. http://www.ssrpm.ch/old/2009/proceedings-2009.pdf.
Scheidegger, Stephan. “Comparison of Image Quality between a Digital Panorama X-Ray Unit with a CdTe-CMOS Detector and Panorama Xray Units with Other Types of Digital Detectors.” SSRMP Annual Scientific Meeting 2009 : University Hospital Basel 19th and 20th of November 2009: Abstracts & Proceedings, SSRMP/DGMP/ÖGMP, 2009, pp. 63–69, http://www.ssrpm.ch/old/2009/proceedings-2009.pdf.


Alle Ressourcen in diesem Repository sind urheberrechtlich geschützt, soweit nicht anderweitig angezeigt.