Publikationstyp: Beitrag in wissenschaftlicher Zeitschrift
Art der Begutachtung: Peer review (Publikation)
Titel: Correction of specimen absorption in X-ray diffuse scattering experiments with area-detector systems
Autor/-in: Scheidegger, Stephan
Estermann, Michael Alexander
Steurer, Steurer
DOI: 10.1107/S0021889899011929
Erschienen in: Journal of Applied Crystallography
Band(Heft): 33
Heft: 1
Seite(n): 35
Seiten bis: 48
Erscheinungsdatum: 2000
Verlag / Hrsg. Institution: Wiley
ISSN: 0021-8898
Sprache: Deutsch
Schlagwörter: Aperiodic material; Diffuse scattering; Area detector systems; Image reconstruction
Fachgebiet (DDC): 540: Chemie
Zusammenfassung: Methods for correcting specimen absorption in X-ray diffraction experiments, dedicated to two-dimensional area-detector systems and broad diffuse scattering phenomena, are implemented and tested. The respective transmission factors, in relation to the crystal or specimen shape, are applied to the intensity of every pixel of the two-dimensional detector. The pixel-wise approach allows for a fully quantitative treatment of continuous diffraction information, such as disorder diffuse scattering or scattering from amorphous materials, which is collected with a two-dimensional detector system. This is in contrast to routine data reduction, where the transmission factors are applied to the integrated Bragg intensities only. Furthermore, it is possible to assign different linear attenuation coefficients to the paths of the incident and scattered beams, as is desirable, for instance, in the case of X-ray holography with an internal resonant scatterer. Broad diffuse scattering data collected with synchrotron radiation and numerical calculations are used to study in detail the influence of experimental parameters on the accuracy of the pixel-wise absorption correction.
URI: https://digitalcollection.zhaw.ch/handle/11475/3534
Volltext Version: Publizierte Version
Lizenz (gemäss Verlagsvertrag): Lizenz gemäss Verlagsvertrag
Departement: School of Engineering
Enthalten in den Sammlungen:Publikationen School of Engineering

Dateien zu dieser Ressource:
Es gibt keine Dateien zu dieser Ressource.
Zur Langanzeige
Scheidegger, S., Estermann, M. A., & Steurer, S. (2000). Correction of specimen absorption in X-ray diffuse scattering experiments with area-detector systems. Journal of Applied Crystallography, 33(1), 35–48. https://doi.org/10.1107/S0021889899011929
Scheidegger, S., Estermann, M.A. and Steurer, S. (2000) ‘Correction of specimen absorption in X-ray diffuse scattering experiments with area-detector systems’, Journal of Applied Crystallography, 33(1), pp. 35–48. Available at: https://doi.org/10.1107/S0021889899011929.
S. Scheidegger, M. A. Estermann, and S. Steurer, “Correction of specimen absorption in X-ray diffuse scattering experiments with area-detector systems,” Journal of Applied Crystallography, vol. 33, no. 1, pp. 35–48, 2000, doi: 10.1107/S0021889899011929.
SCHEIDEGGER, Stephan, Michael Alexander ESTERMANN und Steurer STEURER, 2000. Correction of specimen absorption in X-ray diffuse scattering experiments with area-detector systems. Journal of Applied Crystallography. 2000. Bd. 33, Nr. 1, S. 35–48. DOI 10.1107/S0021889899011929
Scheidegger, Stephan, Michael Alexander Estermann, and Steurer Steurer. 2000. “Correction of specimen absorption in X-ray diffuse scattering experiments with area-detector systems.” Journal of Applied Crystallography 33 (1): 35–48. https://doi.org/10.1107/S0021889899011929.
Scheidegger, Stephan, et al. “Correction of specimen absorption in X-ray diffuse scattering experiments with area-detector systems.” Journal of Applied Crystallography, vol. 33, no. 1, 2000, pp. 35–48, https://doi.org/10.1107/S0021889899011929.


Alle Ressourcen in diesem Repository sind urheberrechtlich geschützt, soweit nicht anderweitig angezeigt.