Publication type: Article in scientific journal
Type of review: Peer review (publication)
Title: A helium beam path for an imaging-plate detector system
Authors: Estermann, Michael A.
Scheidegger, Stephan
Reifler, Hans
Steurer, Walter
DOI: 10.1107/S0021889897005773
Published in: Journal of Applied Crystallography
Volume(Issue): 1997
Issue: 30
Page(s): 1165
Pages to: 1166
Issue Date: 1997
Publisher / Ed. Institution: Wiley
ISSN: 0021-8898
Language: English
Subjects: Imaging plate; Helium beam path; Diffraction
Subject (DDC): 540: Chemistry
Abstract: A helium beam path for the marresearch imaging plate detector system (X-ray Research GmbH, Norderstedt, Germany) is described. The helium beam path is designed to minimize unwanted air scattering of the primary beam and to reduce absorption of the diffracted beam. The standard marresearch detector system, consisting of the imaging plate detector (online scanner) and the detector base with integrated collimation system, remains unchanged. The beam path consists of a polyethylene bag with the open end fixed to a metal ring. The ring is pressed against the entry window of the imaging plate detector. In this way a sealed volume is created. The primary beam enters into the helium bag through an additional collimating system which is sealed with a thin polyimide window. The crystal and the goniometer head are located inside the helium bag and are connected to the outside spindle axis via a linear and rotary motion feedthrough.
URI: https://digitalcollection.zhaw.ch/handle/11475/3523
Fulltext version: Published version
License (according to publishing contract): Licence according to publishing contract
Departement: School of Engineering
Appears in collections:Publikationen School of Engineering

Files in This Item:
There are no files associated with this item.
Show full item record
Estermann, M. A., Scheidegger, S., Reifler, H., & Steurer, W. (1997). A helium beam path for an imaging-plate detector system. Journal of Applied Crystallography, 1997(30), 1165–1166. https://doi.org/10.1107/S0021889897005773
Estermann, M.A. et al. (1997) ‘A helium beam path for an imaging-plate detector system’, Journal of Applied Crystallography, 1997(30), pp. 1165–1166. Available at: https://doi.org/10.1107/S0021889897005773.
M. A. Estermann, S. Scheidegger, H. Reifler, and W. Steurer, “A helium beam path for an imaging-plate detector system,” Journal of Applied Crystallography, vol. 1997, no. 30, pp. 1165–1166, 1997, doi: 10.1107/S0021889897005773.
ESTERMANN, Michael A., Stephan SCHEIDEGGER, Hans REIFLER und Walter STEURER, 1997. A helium beam path for an imaging-plate detector system. Journal of Applied Crystallography. 1997. Bd. 1997, Nr. 30, S. 1165–1166. DOI 10.1107/S0021889897005773
Estermann, Michael A., Stephan Scheidegger, Hans Reifler, and Walter Steurer. 1997. “A Helium Beam Path for an Imaging-Plate Detector System.” Journal of Applied Crystallography 1997 (30): 1165–66. https://doi.org/10.1107/S0021889897005773.
Estermann, Michael A., et al. “A Helium Beam Path for an Imaging-Plate Detector System.” Journal of Applied Crystallography, vol. 1997, no. 30, 1997, pp. 1165–66, https://doi.org/10.1107/S0021889897005773.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.