Publication type: Article in scientific journal
Type of review: Peer review (publication)
Title: Potentiometric Immunoassay with Quantum Dot Labels
Authors: Thürer, Reto
Vigassy, Tamás
Hirayama, Martina
Wang, Joseph
Bakker, Eric
Pretsch, Ernö
DOI: 10.1021/ac070932m
Published in: Analytical Chemistry
Volume(Issue): 79
Issue: 13
Page(s): 5107
Pages to: 5110
Issue Date: 26-May-2007
Publisher / Ed. Institution: American Chemical Society
Publisher / Ed. Institution: Washington
ISSN: 0003-2700
1520-6882
Language: English
Subjects: Immunoassay; Potentiometric; Quantum dot
Subject (DDC): 540: Chemistry
Abstract: Potentiometric sensors based on polymer membrane electrodes, if properly optimized, are useful for measurements at trace levels. The expected independence of the electrochemical signal of the sample size makes them extremely attractive for measurements in small volumes. Here, we report on electrodes for the potentiometric detection of cadmium ions that reach a detection limit of 6 nM and utilize a Na+-selective electrode as pseudoreference in order to facilitate measurements in 150-µL samples. A potentiometric immunoassay of mouse IgG is performed via CdSe quantum dot labels on a secondary antibody according to a sandwich immunoassay protocol in a microtiter plate format. The CdSe quantum dots are found to be easily dissolved/oxidized in a matter of minutes with hydrogen peroxide, allowing us to maintain the pH at a near-neutral value. The potentiometric protein immunoassay exhibits a log-linear response ranging from 0.15 to 4.0 pmol of IgG, with a detection limit of <10 fmol in 150-µL sample wells.
URI: https://digitalcollection.zhaw.ch/handle/11475/3018
Fulltext version: Published version
License (according to publishing contract): Licence according to publishing contract
Departement: School of Engineering
Appears in collections:Publikationen School of Engineering

Files in This Item:
There are no files associated with this item.
Show full item record
Thürer, R., Vigassy, T., Hirayama, M., Wang, J., Bakker, E., & Pretsch, E. (2007). Potentiometric Immunoassay with Quantum Dot Labels. Analytical Chemistry, 79(13), 5107–5110. https://doi.org/10.1021/ac070932m
Thürer, R. et al. (2007) ‘Potentiometric Immunoassay with Quantum Dot Labels’, Analytical Chemistry, 79(13), pp. 5107–5110. Available at: https://doi.org/10.1021/ac070932m.
R. Thürer, T. Vigassy, M. Hirayama, J. Wang, E. Bakker, and E. Pretsch, “Potentiometric Immunoassay with Quantum Dot Labels,” Analytical Chemistry, vol. 79, no. 13, pp. 5107–5110, May 2007, doi: 10.1021/ac070932m.
THÜRER, Reto, Tamás VIGASSY, Martina HIRAYAMA, Joseph WANG, Eric BAKKER und Ernö PRETSCH, 2007. Potentiometric Immunoassay with Quantum Dot Labels. Analytical Chemistry. 26 Mai 2007. Bd. 79, Nr. 13, S. 5107–5110. DOI 10.1021/ac070932m
Thürer, Reto, Tamás Vigassy, Martina Hirayama, Joseph Wang, Eric Bakker, and Ernö Pretsch. 2007. “Potentiometric Immunoassay with Quantum Dot Labels.” Analytical Chemistry 79 (13): 5107–10. https://doi.org/10.1021/ac070932m.
Thürer, Reto, et al. “Potentiometric Immunoassay with Quantum Dot Labels.” Analytical Chemistry, vol. 79, no. 13, May 2007, pp. 5107–10, https://doi.org/10.1021/ac070932m.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.