Please use this identifier to cite or link to this item: https://doi.org/10.21256/zhaw-4903
Publication type: Conference paper
Type of review: Not specified
Title: Intercomparison of pulsed solar simulator measurements between the mobile flasher bus and stationary calibration laboratories
Authors: Baumgartner, Franz
Schär, Daniel
Pezzotti, M.
Haller, J.
Polverini, D.
Tzamalis, G.
Zaaiman, W.
DOI: 10.21256/zhaw-4903
10.4229/26thEUPVSEC2011-4AV.1.27
Proceedings: Proceedings of the 26th European Photovoltaic Solar Energy Conference and Exhibition EUPVSEC
Page(s): 3374
Pages to: 3377
Conference details: 26th European Photovoltaic Solar Energy Conference and Exhibition (EU PVSEC), Hamburg, Germany, 5-9 September 2011
Issue Date: 2011
Publisher / Ed. Institution: WIP
ISBN: 3-936338-27-2
Language: English
Subject (DDC): 621.3: Electrical, communications, control engineering
Abstract: The Swiss Mobile Flasher Bus (SMFB) is equipped with a standard high-quality flasher and a very high throughput of up to 200 PV modules per day could be reached direct at customer site. Recently an analysis of the SMFB’s measurement uncertainty budget was presented, resulted in an expanded combined uncertainty of ±3% at a 95% confidence level for standard crystalline Silicon modules. This uncertainty value is about 1% larger than values of the best stationary test labs but enables still very accurate measurements at ambient temperature conditions with the advantage to make more measurements directly on customer’s site. In this paper this uncertainty values were tested by intercomparison of measurement results of the SMFB and the stationary JRC ESTI laboratory on the same PV modules performed within the same hour to reduce uncertainty contributions by instability of the device under test DUT. The largest difference of nominal power measurements was found to be smaller 0.5% for polycrystalline standard modules including the precision measurement at Fraunhofer ISE on the same DUT performed 20 months before. Measurements on standard thin film CIS PV modules resulted in deviations up to 3.7% which are within the calculated SMFB overall uncertainty value of 4%. No light pre-conditioning was performed to the CIS modules and different flasher pulse length was used, 10ms for the SMFB and 1.2ms for the stationary laboratory flasher. In a second intercomparison run the spectral response measurement on module level of SMFB and the JRC ESTI was performed by the use of band pass filters of about 50nm width. The good correlation of the results show that the SMFB spectral response measurement is valuable to calculate the spectral mismatch factor to account for different spectral characteristics of measured PV module, the used monitor cell and the flashers spectra to optimise the overall measurement uncertainty of the SMFB.
URI: https://digitalcollection.zhaw.ch/handle/11475/13312
Fulltext version: Published version
License (according to publishing contract): Licence according to publishing contract
Departement: School of Engineering
Organisational Unit: Institute of Energy Systems and Fluid Engineering (IEFE)
Appears in collections:Publikationen School of Engineering

Files in This Item:
File Description SizeFormat 
2011_Baumgartner_Intercomparison_of_pulsed_solar_simulator_measurements.pdf651.65 kBAdobe PDFThumbnail
View/Open
Show full item record
Baumgartner, F., Schär, D., Pezzotti, M., Haller, J., Polverini, D., Tzamalis, G., & Zaaiman, W. (2011). Intercomparison of pulsed solar simulator measurements between the mobile flasher bus and stationary calibration laboratories [Conference paper]. Proceedings of the 26th European Photovoltaic Solar Energy Conference and Exhibition EUPVSEC, 3374–3377. https://doi.org/10.21256/zhaw-4903
Baumgartner, F. et al. (2011) ‘Intercomparison of pulsed solar simulator measurements between the mobile flasher bus and stationary calibration laboratories’, in Proceedings of the 26th European Photovoltaic Solar Energy Conference and Exhibition EUPVSEC. WIP, pp. 3374–3377. Available at: https://doi.org/10.21256/zhaw-4903.
F. Baumgartner et al., “Intercomparison of pulsed solar simulator measurements between the mobile flasher bus and stationary calibration laboratories,” in Proceedings of the 26th European Photovoltaic Solar Energy Conference and Exhibition EUPVSEC, 2011, pp. 3374–3377. doi: 10.21256/zhaw-4903.
BAUMGARTNER, Franz, Daniel SCHÄR, M. PEZZOTTI, J. HALLER, D. POLVERINI, G. TZAMALIS und W. ZAAIMAN, 2011. Intercomparison of pulsed solar simulator measurements between the mobile flasher bus and stationary calibration laboratories. In: Proceedings of the 26th European Photovoltaic Solar Energy Conference and Exhibition EUPVSEC. Conference paper. WIP. 2011. S. 3374–3377. ISBN 3-936338-27-2
Baumgartner, Franz, Daniel Schär, M. Pezzotti, J. Haller, D. Polverini, G. Tzamalis, and W. Zaaiman. 2011. “Intercomparison of Pulsed Solar Simulator Measurements between the Mobile Flasher Bus and Stationary Calibration Laboratories.” Conference paper. In Proceedings of the 26th European Photovoltaic Solar Energy Conference and Exhibition EUPVSEC, 3374–77. WIP. https://doi.org/10.21256/zhaw-4903.
Baumgartner, Franz, et al. “Intercomparison of Pulsed Solar Simulator Measurements between the Mobile Flasher Bus and Stationary Calibration Laboratories.” Proceedings of the 26th European Photovoltaic Solar Energy Conference and Exhibition EUPVSEC, WIP, 2011, pp. 3374–77, https://doi.org/10.21256/zhaw-4903.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.