dc.contributor.authorCarigiet, Fabian-
dc.contributor.authorBaumgartner, Franz-
dc.contributor.authorSutterlueti, Juergen-
dc.contributor.authorAllet, Nicolas-
dc.contributor.authorPezzotti, Manuel-
dc.contributor.authorHaller, Joerg-
dc.date.accessioned2018-11-02T09:32:27Z-
dc.date.available2018-11-02T09:32:27Z-
dc.date.issued2013-
dc.identifier.isbn3-936338-33-7de_CH
dc.identifier.urihttps://digitalcollection.zhaw.ch/handle/11475/12503-
dc.description.abstractYield forecasting of the commercial design tool PVsyst (v5.6) is compared to the performance measurements of multi crystalline modules in Dietikon, Zurich, during 2011. The total measured horizontal irradiance was 1146 kWh/m2 in 2011. This pyranometer measurement covers 91.5% of the total annual irradiance (determined using IDAWEB data with 100% uptime for Affoltern). The historical irradiance data averaged over decades are about 11.4% (Meteonorm) or 13.6% (PVGIS) lower than the IDAWEB data in 2011. The standard deviation between 2001 and 2011 is about 4.9% with respect to IDAWEB. The measured DC performance ratio (PRDC) is 0.937 with a measurement uncertainty of ±0.031 (k=2). Simulations with manufacturer and optimised parameters showed a deviation to the measurement between 4% and 8%. A second analysis considers shading losses for different shading angles. Calculated losses are about 2% lower than simulated losses with PVsyst using a model of partial shading for a shading angle of 20°. Interesting results could be achieved by determining the loss upon limiting the inverter output power. There is only 4.4% annual loss when the inverter output power is set to a limit of 70 % for the location Dietikon in 2011.de_CH
dc.language.isoende_CH
dc.publisherWIP-Renewable Energiesde_CH
dc.rightsLicence according to publishing contractde_CH
dc.subjectYield Forecastde_CH
dc.subjectInverterde_CH
dc.subjectPerformancede_CH
dc.subjectShadingde_CH
dc.subject.ddc621.3: Elektro-, Kommunikations-, Steuerungs- und Regelungstechnikde_CH
dc.titleVerification of measured PV energy yield versus forecast and loss analysisde_CH
dc.typeKonferenz: Paperde_CH
dcterms.typeTextde_CH
zhaw.departementSchool of Engineeringde_CH
zhaw.organisationalunitInstitut für Energiesysteme und Fluid-Engineering (IEFE)de_CH
dc.identifier.doi10.4229/28thEUPVSEC2013-5BV.4.25de_CH
zhaw.conference.details28th European Photovoltaic Solar Energy Conference and Exhibition (EU PVSEC), Paris, France, 30 September - 4 October 2013de_CH
zhaw.funding.euNode_CH
zhaw.originated.zhawYesde_CH
zhaw.publication.statuspublishedVersionde_CH
zhaw.publication.reviewPeer review (Abstract)de_CH
zhaw.title.proceedings28th European photovoltaic solar energy conference and exhibition : the most inspiringplatform for the global PV solar sector : Parc des Expositions Paris Nord Villepinte, Paris, France : conference, 30 Sep-04 Oct 2013de_CH
zhaw.webfeedPhotovoltaikde_CH
Appears in collections:Publikationen School of Engineering

Files in This Item:
There are no files associated with this item.
Show simple item record
Carigiet, F., Baumgartner, F., Sutterlueti, J., Allet, N., Pezzotti, M., & Haller, J. (2013). Verification of measured PV energy yield versus forecast and loss analysis. 28th European Photovoltaic Solar Energy Conference and Exhibition : The Most Inspiringplatform for the Global PV Solar Sector : Parc Des Expositions Paris Nord Villepinte, Paris, France : Conference, 30 Sep-04 Oct 2013. https://doi.org/10.4229/28thEUPVSEC2013-5BV.4.25
Carigiet, F. et al. (2013) ‘Verification of measured PV energy yield versus forecast and loss analysis’, in 28th European photovoltaic solar energy conference and exhibition : the most inspiringplatform for the global PV solar sector : Parc des Expositions Paris Nord Villepinte, Paris, France : conference, 30 Sep-04 Oct 2013. WIP-Renewable Energies. Available at: https://doi.org/10.4229/28thEUPVSEC2013-5BV.4.25.
F. Carigiet, F. Baumgartner, J. Sutterlueti, N. Allet, M. Pezzotti, and J. Haller, “Verification of measured PV energy yield versus forecast and loss analysis,” in 28th European photovoltaic solar energy conference and exhibition : the most inspiringplatform for the global PV solar sector : Parc des Expositions Paris Nord Villepinte, Paris, France : conference, 30 Sep-04 Oct 2013, 2013. doi: 10.4229/28thEUPVSEC2013-5BV.4.25.
CARIGIET, Fabian, Franz BAUMGARTNER, Juergen SUTTERLUETI, Nicolas ALLET, Manuel PEZZOTTI und Joerg HALLER, 2013. Verification of measured PV energy yield versus forecast and loss analysis. In: 28th European photovoltaic solar energy conference and exhibition : the most inspiringplatform for the global PV solar sector : Parc des Expositions Paris Nord Villepinte, Paris, France : conference, 30 Sep-04 Oct 2013. Conference paper. WIP-Renewable Energies. 2013. ISBN 3-936338-33-7
Carigiet, Fabian, Franz Baumgartner, Juergen Sutterlueti, Nicolas Allet, Manuel Pezzotti, and Joerg Haller. 2013. “Verification of Measured PV Energy Yield versus Forecast and Loss Analysis.” Conference paper. In 28th European Photovoltaic Solar Energy Conference and Exhibition : The Most Inspiringplatform for the Global PV Solar Sector : Parc Des Expositions Paris Nord Villepinte, Paris, France : Conference, 30 Sep-04 Oct 2013. WIP-Renewable Energies. https://doi.org/10.4229/28thEUPVSEC2013-5BV.4.25.
Carigiet, Fabian, et al. “Verification of Measured PV Energy Yield versus Forecast and Loss Analysis.” 28th European Photovoltaic Solar Energy Conference and Exhibition : The Most Inspiringplatform for the Global PV Solar Sector : Parc Des Expositions Paris Nord Villepinte, Paris, France : Conference, 30 Sep-04 Oct 2013, WIP-Renewable Energies, 2013, https://doi.org/10.4229/28thEUPVSEC2013-5BV.4.25.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.