Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Scheidegger, Stephan | - |
dc.date.accessioned | 2018-03-08T13:58:37Z | - |
dc.date.available | 2018-03-08T13:58:37Z | - |
dc.date.issued | 2009 | - |
dc.identifier.isbn | 3-908-125-49-9 | de_CH |
dc.identifier.uri | http://www.ssrpm.ch/old/2009/proceedings-2009.pdf | de_CH |
dc.identifier.uri | https://digitalcollection.zhaw.ch/handle/11475/3559 | - |
dc.description.abstract | An investigation of the image quality of 5 panoramic X-ray units was carried out for this paper. Measurement of the MTF clearly shows good resolution for the Art Plus unit (MTF(50%) = 5.61 lp / mm) compared to the average of all 5 of the units (3.44 ± 1.55 lp /mm). To investigate image noise, the ratio was calculated between average gray scale value and standard deviation in a 32 × 32 matrix (R32x32). Compared to the other units, identical regions in the image are less noisy for the Art Plus unit (32x32 R = 92.28 and 32x32 R = 19.40 ± 11.00 for the other units). Also image displacement of a series of images was determined for the Art Plus and the Pro Max unit. The displacements were between 1-5 Pixels for both. | de_CH |
dc.language.iso | en | de_CH |
dc.publisher | SSRMP/DGMP/ÖGMP | de_CH |
dc.rights | Licence according to publishing contract | de_CH |
dc.subject | CDTE-CMOS | de_CH |
dc.subject | Digital detector | de_CH |
dc.subject | Panorama x-ray unit | de_CH |
dc.subject.ddc | 530: Physik | de_CH |
dc.subject.ddc | 616: Innere Medizin und Krankheiten | de_CH |
dc.title | Comparison of image quality between a digital panorama X-ray unit with a CdTe-CMOS detector and panorama Xray units with other types of digital detectors | de_CH |
dc.type | Konferenz: Paper | de_CH |
dcterms.type | Text | de_CH |
zhaw.departement | School of Engineering | de_CH |
zhaw.publisher.place | Basel | de_CH |
zhaw.conference.details | Annual Scientific Meeting 2009 der Schweizerischen Gesellschaft für Strahlenbiologie und Medizinische Physik (SSRMP), Basel, 19-20 November 2009 | de_CH |
zhaw.funding.eu | No | de_CH |
zhaw.originated.zhaw | Yes | de_CH |
zhaw.pages.end | 69 | de_CH |
zhaw.pages.start | 63 | de_CH |
zhaw.publication.status | publishedVersion | de_CH |
zhaw.publication.review | Not specified | de_CH |
zhaw.title.proceedings | SSRMP Annual Scientific Meeting 2009 : University Hospital Basel 19th and 20th of November 2009: Abstracts & Proceedings | de_CH |
Appears in collections: | Publikationen School of Engineering |
Files in This Item:
There are no files associated with this item.
Show simple item record
Scheidegger, S. (2009). Comparison of image quality between a digital panorama X-ray unit with a CdTe-CMOS detector and panorama Xray units with other types of digital detectors [Conference paper]. SSRMP Annual Scientific Meeting 2009 : University Hospital Basel 19th and 20th of November 2009: Abstracts & Proceedings, 63–69. http://www.ssrpm.ch/old/2009/proceedings-2009.pdf
Scheidegger, S. (2009) ‘Comparison of image quality between a digital panorama X-ray unit with a CdTe-CMOS detector and panorama Xray units with other types of digital detectors’, in SSRMP Annual Scientific Meeting 2009 : University Hospital Basel 19th and 20th of November 2009: Abstracts & Proceedings. Basel: SSRMP/DGMP/ÖGMP, pp. 63–69. Available at: http://www.ssrpm.ch/old/2009/proceedings-2009.pdf.
S. Scheidegger, “Comparison of image quality between a digital panorama X-ray unit with a CdTe-CMOS detector and panorama Xray units with other types of digital detectors,” in SSRMP Annual Scientific Meeting 2009 : University Hospital Basel 19th and 20th of November 2009: Abstracts & Proceedings, 2009, pp. 63–69. [Online]. Available: http://www.ssrpm.ch/old/2009/proceedings-2009.pdf
SCHEIDEGGER, Stephan, 2009. Comparison of image quality between a digital panorama X-ray unit with a CdTe-CMOS detector and panorama Xray units with other types of digital detectors. In: SSRMP Annual Scientific Meeting 2009 : University Hospital Basel 19th and 20th of November 2009: Abstracts & Proceedings [online]. Conference paper. Basel: SSRMP/DGMP/ÖGMP. 2009. S. 63–69. ISBN 3-908-125-49-9. Verfügbar unter: http://www.ssrpm.ch/old/2009/proceedings-2009.pdf
Scheidegger, Stephan. 2009. “Comparison of Image Quality between a Digital Panorama X-Ray Unit with a CdTe-CMOS Detector and Panorama Xray Units with Other Types of Digital Detectors.” Conference paper. In SSRMP Annual Scientific Meeting 2009 : University Hospital Basel 19th and 20th of November 2009: Abstracts & Proceedings, 63–69. Basel: SSRMP/DGMP/ÖGMP. http://www.ssrpm.ch/old/2009/proceedings-2009.pdf.
Scheidegger, Stephan. “Comparison of Image Quality between a Digital Panorama X-Ray Unit with a CdTe-CMOS Detector and Panorama Xray Units with Other Types of Digital Detectors.” SSRMP Annual Scientific Meeting 2009 : University Hospital Basel 19th and 20th of November 2009: Abstracts & Proceedings, SSRMP/DGMP/ÖGMP, 2009, pp. 63–69, http://www.ssrpm.ch/old/2009/proceedings-2009.pdf.