Publikationstyp: Konferenz: Sonstiges
Art der Begutachtung: Peer review (Abstract)
Titel: Comparison of stirred single-use bioreactors : case study of an IgG production process
Autor/-in: Schirmer, Cedric
Kienle, Klaus
et. al: No
Angaben zur Konferenz: BioTech 2019 : Biopharmaceutical Manufacturing and Single-Use Technologies, Wädenswil, Switzerland, 2-4 July 2019
Erscheinungsdatum: Jul-2019
Sprache: Englisch
Fachgebiet (DDC): 660: Technische Chemie
Zusammenfassung: Today, the benefits of single-use (SU) technologies for upstream processing are much more prevalent and heavily adopted within the biopharmaceutical industry. Pall has developed the Allegro™ STR stirred single-use bioreactor family which is currently available in 4 sizes: STR 50, STR 200, STR 1000, and STR 2000 (Figure 1). The direct-bottom mechanically driven impeller allows a large range of power inputs from 0.002 W/kg up to 0.3 W/kg, while the macro sparger seated below the three 45-degree elephant ear blades results in high oxygen transfer rates (kLa up to 40 h-1) and short mixing times (minimum tM~10 s). Previous studies highlighted that the critical parameters to be kept constant from one scale to another are the volumetric power input (P/V) for agitation and the superficial gas velocity (vs) for aeration. This will successfully scale up a process at a constant kLa, keeping equivalent mixing time and shear stress environment in the bioreactor. In this case study the stirred SU bioreactor Allegro STR 200 from PALL has been tested and compared against a conventional, cylindrically shaped SU 200 L bioreactor regarding the growth and the monoclonal antibody production (mAb) of a Chinese hamster ovary (CHO) cell line in a chemically defined, animal‐derived component-free (ADCF) medium optimized for high‐yield protein production with a fed‐batch process intended for use in combination with specific feed supplements. Comparable results could be achieved in both stirred bioreactors. The average peak cell density at the end of the growth phase was 2.15·107 cells·mL-1, which correlated with a decrease in viability. The specific growth rate during the exponential growth phase was 0.028 h-1. As expected, the mAb titer increased to an average level of 2.18 g·L-1 at the culture harvest and only small amounts of aggregates or low molecular weight species were found. This allows to conclude, that the shear stress acting on the cells under the selected process parameters does not impair the mAb quality in the AllegroTM STR 200.
URI: https://digitalcollection.zhaw.ch/handle/11475/19326
Volltext Version: Publizierte Version
Lizenz (gemäss Verlagsvertrag): Keine Angabe
Departement: Life Sciences und Facility Management
Organisationseinheit: Institut für Chemie und Biotechnologie (ICBT)
Enthalten in den Sammlungen:Publikationen Life Sciences und Facility Management

Dateien zu dieser Ressource:
Es gibt keine Dateien zu dieser Ressource.
Zur Langanzeige
Schirmer, C., & Kienle, K. (2019, July). Comparison of stirred single-use bioreactors : case study of an IgG production process. BioTech 2019 : Biopharmaceutical Manufacturing and Single-Use Technologies, Wädenswil, Switzerland, 2-4 July 2019.
Schirmer, C. and Kienle, K. (2019) ‘Comparison of stirred single-use bioreactors : case study of an IgG production process’, in BioTech 2019 : Biopharmaceutical Manufacturing and Single-Use Technologies, Wädenswil, Switzerland, 2-4 July 2019.
C. Schirmer and K. Kienle, “Comparison of stirred single-use bioreactors : case study of an IgG production process,” in BioTech 2019 : Biopharmaceutical Manufacturing and Single-Use Technologies, Wädenswil, Switzerland, 2-4 July 2019, Jul. 2019.
SCHIRMER, Cedric und Klaus KIENLE, 2019. Comparison of stirred single-use bioreactors : case study of an IgG production process. In: BioTech 2019 : Biopharmaceutical Manufacturing and Single-Use Technologies, Wädenswil, Switzerland, 2-4 July 2019. Conference presentation. Juli 2019
Schirmer, Cedric, and Klaus Kienle. 2019. “Comparison of Stirred Single-Use Bioreactors : Case Study of an IgG Production Process.” Conference presentation. In BioTech 2019 : Biopharmaceutical Manufacturing and Single-Use Technologies, Wädenswil, Switzerland, 2-4 July 2019.
Schirmer, Cedric, and Klaus Kienle. “Comparison of Stirred Single-Use Bioreactors : Case Study of an IgG Production Process.” BioTech 2019 : Biopharmaceutical Manufacturing and Single-Use Technologies, Wädenswil, Switzerland, 2-4 July 2019, 2019.


Alle Ressourcen in diesem Repository sind urheberrechtlich geschützt, soweit nicht anderweitig angezeigt.